Product Comparison
UPS 1 [x] | UPS 2 [x] | UPS 3 [x] | |
General features | |||
Model | |||
Main Picture | ![]() | ![]() | ![]() |
Pictures | |||
Item Number | 10121104 | 10121104 | 10121104 |
EAN | 4260074981612 | 4260074981612 | 4260074981612 |
Features |
|
|
|
Type | Line-Interactive | Line-Interactive | Line-Interactive |
Power capacity | 2000VA / 1400W | 2000VA / 1400W | 2000VA / 1400W |
Output Power Factor | 0.70 | 0.70 | 0.70 |
Input | |||
Input Voltage Range | 162-290 VAC | 162-290 VAC | 162-290 VAC |
Frequency (Synchronized Range) | 50Hz or 60Hz | 50Hz or 60Hz | 50Hz or 60Hz |
Output | |||
Nominal Output Voltage | 208/220/230/240 VAC | 208/220/230/240 VAC | 208/220/230/240 VAC |
Pure Sine Wave | Yes | Yes | Yes |
THDv | ≤2% @ 100% linear load, ≤5% @ 100% non-linear load (before low battery alarm) | ≤2% @ 100% linear load, ≤5% @ 100% non-linear load (before low battery alarm) | ≤2% @ 100% linear load, ≤5% @ 100% non-linear load (before low battery alarm) |
Voltage Regulation (Bat. Mod.) | ±1.5% (before battery alarm) | ±1.5% (before battery alarm) | ±1.5% (before battery alarm) |
Frequency (Battery Mode) | ±1Hz | ±1Hz | ±1Hz |
Technical details | |||
Load Crest Ratio | 3:1 | 3:1 | 3:1 |
Transfer Time [AC to Battery] | 2-6ms (typical, 10ms max) | 2-6ms (typical, 10ms max) | 2-6ms (typical, 10ms max) |
Charger | 1.4A | 1.4A | 1.4A |
Protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection |
Fan Logic | Controlled by adjusting fan speed in 5% steps. Fan off under 40degC; line mode; batteries charged | Controlled by adjusting fan speed in 5% steps. Fan off under 40degC; line mode; batteries charged | Controlled by adjusting fan speed in 5% steps. Fan off under 40degC; line mode; batteries charged |
LCD Indicators | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
Efficiency | |||
LINE mode full Load | 96.0% | 96.0% | 96.0% |
BATTERY mode full Load | 90.0% | 90.0% | 90.0% |
Energy Star compliance | t | t | t |
Batteries and autonomy time | |||
Batteries | 4x 12V/7Ah | 4x 12V/7Ah | 4x 12V/7Ah |
DC Voltage | 4 x 12V | 4 x 12V | 4 x 12V |
Recharge Time | 4h to 90% | 4h to 90% | 4h to 90% |
Full Load Backup Time | 2.5min | 2.5min | 2.5min |
Half Load Backup Time | 8min | 8min | 8min |
Connections and communication | |||
IEC C13 Outlet | 8 | 8 | 8 |
Programmable Outlets | 4 | 4 | 4 |
Input | C20 | C20 | C20 |
Software | ViewPower | ViewPower | ViewPower |
USB port | Yes | Yes | Yes |
HID Support | Yes | Yes | Yes |
RS-232 Port | Yes | Yes | Yes |
Extension Slot | Yes, 1 | Yes, 1 | Yes, 1 |
EPO Port | Yes | Yes | Yes |
Environment | |||
Noise Level | < 45dB | < 45dB | < 45dB |
Temperature | 0°C – 40°C | 0°C – 40°C | 0°C – 40°C |
Humidity | 20% - 90% RH (non-condensing) | 20% - 90% RH (non-condensing) | 20% - 90% RH (non-condensing) |
IEC 62040-3 classification | VI-SS-211 | VI-SS-211 | VI-SS-211 |
Logistics | |||
Package Content | UPS, Manual, USB Cable, Input Power Cable, 2x IEC Cable | UPS, Manual, USB Cable, Input Power Cable, 2x IEC Cable | UPS, Manual, USB Cable, Input Power Cable, 2x IEC Cable |
Manual Languages | EN | EN | EN |
Width | 145mm | 145mm | 145mm |
Height | 220mm | 220mm | 220mm |
Depth | 455mm | 455mm | 455mm |
Weight | 18.1kg | 18.1kg | 18.1kg |
Giftbox - Width | 235mm | 235mm | 235mm |
Giftbox - Height | 325mm | 325mm | 325mm |
Giftbox - Depth | 540mm | 540mm | 540mm |
Giftbox - Weight | 20.1kg | 20.1kg | 20.1kg |